The Vertical Text Generator is ready to use online, while a command-line approach requires your own Unicode-aware script because the product has no documented command-line interface.
For most one-off jobs, the online browser workflow is faster: paste the source, choose a height and direction, inspect the preview, and download UTF-8 TXT. Segmentation, layout, previewing, and download creation happen locally, and the text is not uploaded to Lizely. A command-line solution becomes useful when the same conversion must run repeatedly inside a script, file-processing pipeline, or scheduled job, but then you own the Unicode logic, validation, and file output.

Command line versus online: the practical tradeoffs
The main difference is not the visual result but who manages the transformation. The browser tool supplies the layout engine and its controls; a custom CLI supplies the automation while adding code you must maintain.
| Consideration | Online browser workflow | Command-line workflow |
|---|---|---|
| Best fit | Interactive, one-off conversions that need a preview and downloadable TXT. | Repeated conversions inside scripts, pipelines, or scheduled jobs. |
| Setup | Use the browser tool without building a separate utility. | Select or create a runtime, segmenter, command parser, and output writer. |
| Unicode handling | Built-in grapheme segmentation with the site's tested fallback. | Your code must segment grapheme clusters and reproduce the line-boundary rules. |
| Privacy | Segmentation, layout, previewing, and download creation happen locally; text is not uploaded to Lizely. | Depends on the implementation. Local execution can avoid network access, but remote dependencies change that claim. |
| Output | An exact monospaced preview and a matching UTF-8 TXT download. | The format is implementation-dependent; matching the online result requires identical cell rules. |
| Failure handling | Invalid input or settings produce explicit errors without a partial result. | Validation, messages, and exit behavior depend on your implementation. |
| Repeatability | The same browser segmentation behavior, source, height, and direction produce the same cell order. | Results depend on the runtime, segmenter, and layout code you use. |
| Ownership | The tool handles segmentation and column layout. | You maintain the code, dependencies, tests, and output format. |
There is no documented Lizely command, executable name, or flag syntax to install. A custom CLI is therefore a separate implementation rather than another front end for the online tool. It makes sense when automation savings clearly outweigh the cost of maintaining and testing Unicode-sensitive code.
Generate a vertical layout online
The browser workflow is the supported path for this product and is the quickest route to copyable or downloadable vertical plain text.
- Enter the source text and choose a column height. Paste or type the text, then select a whole-number height from 1 through 100. The height determines how many grapheme clusters can occupy one logical column before the next column begins.
- Select the column direction. Choose left-to-right to place the first source column at the visual left, or right-to-left to place it at the visual right. The latter matches a common traditional vertical reading direction.
- Generate and inspect the result. Review the exact monospaced preview along with the reported source grapheme count and output column count. If the chosen height would create more than 50 columns, the tool asks for a taller column rather than producing an extremely wide preview.
- Copy or download the finished text. The downloadable UTF-8 TXT matches the preview string exactly and uses LF row separators. Copy the preview when you need the same plain-text arrangement in another application.
The first source graphemes fill the first logical column from top to bottom until the chosen height is reached, and remaining graphemes continue through subsequent columns. Rows use two ordinary spaces between columns. Internal missing cells become full-width blanks to preserve alignment, while missing cells at the visual right edge are omitted.
Each existing CRLF, standalone CR, or LF boundary becomes one full-width blank cell. Consecutive line endings create consecutive blank cells, and a line boundary does not start an independent vertical block. Changing the text, height, or direction clears the previous result so an outdated layout cannot be mistaken for the current one.
Build a command-line equivalent
A faithful CLI starts with Unicode grapheme segmentation rather than raw UTF-16 code units. MDN's Intl.Segmenter reference describes browser segmentation, while Unicode UAX #29 defines grapheme-cluster boundaries. A command-line runtime may expose Intl.Segmenter or provide another segmenter that follows those rules.
- Choose the runtime and segmenter. Test common joined emoji, combining accents, skin-tone modifiers, flags, and variation selectors. Splitting raw code units can separate characters that the tool intentionally keeps together.
- Define the command inputs. For output compatible with the online tool, accept source text, a whole-number height from 1 through 100, a left-to-right or right-to-left direction, and an output destination. The exact command syntax belongs to your implementation.
- Validate before layout. Reject malformed UTF-16 surrogate sequences and empty input before segmentation. Reject decimal or out-of-range heights and invalid directions. Do not create a partial output when validation fails.
- Normalize line boundaries and segment the text. Convert each CRLF, standalone CR, or LF boundary into one full-width blank cell. Segment the resulting text into grapheme clusters and enforce the 5,000-cluster input limit without silently truncating it.
- Slice columns and apply direction. Fill the first logical column from top to bottom, continue through later columns, and stop with an error or taller-height request if the result would exceed 50 columns. Right-to-left mode should reverse only the display order of the columns, not the order of graphemes inside them.
- Render, save, and verify. Join columns with two ordinary spaces, represent internal missing cells with full-width blanks, omit missing cells at the visual right edge, and join rows with LF. Write UTF-8 text and confirm that the saved file matches the preview and keeps complete emoji clusters intact.
This procedure is a compatibility specification, not an official Lizely command. If you maintain the script, use online results at several heights and directions as test cases; differences in segmentation or blank-cell handling will be easier to detect with emoji and multiline inputs included.
Limits and errors in the online generator
The browser tool has explicit boundaries that affect whether it can complete a request.
- Input: The source may contain up to 5,000 Unicode grapheme clusters.
- Height: The column height must be a whole number from 1 through 100.
- Width: The result may contain at most 50 columns. If a short height would exceed that limit, the tool requests a taller column.
- Unicode: Malformed UTF-16 surrogate sequences are rejected before segmentation.
- Errors: Empty input, decimal or out-of-range heights, invalid directions, excessive grapheme counts, and excessive column counts produce explicit errors without a partial result. Source text is never silently truncated.
- Format: The result is plain text, not CSS markup, an image, or a document layout. The downloaded file is UTF-8 TXT and exactly matches the current preview.
These limits belong to the online product. A separate CLI can define different limits, but it will no longer be guaranteed to reproduce the browser tool unless it enforces the same constraints and layout rules.
Where vertical plain text works
The online generator is suited to decorative captions, poetry experiments, vertical labels, short bilingual displays, classroom examples, social posts, and plain-text mockups. It is also a practical choice when the result must remain selectable, copyable, and portable without depending on a particular web page.
It is not a typesetting engine for Japanese tate-chu-yoko, rotated punctuation, ruby annotations, Chinese line breaking, Mongolian layout, bidirectional shaping, or print publishing. Moving the same process to a CLI does not change that limitation: it still produces arranged plain-text cells rather than semantic page typography.
For a real website, CSS writing-mode and language-appropriate typography usually provide a more accessible vertical layout because the text remains responsive and selectable without inserted spaces. For print or graphics, a design application can control glyph rotation, metrics, and page geometry more reliably. A command-line workflow is useful for automating the plain-text output, but it does not replace either of those specialized publishing paths.
Preview before publishing and make the final choice
A correct plain-text cell sequence can still look uneven in the destination. Visible glyphs may render differently across fonts and systems, and alignment depends on the font treating the chosen characters and full-width blank consistently. Proportional fonts, fallback emoji fonts, tabs, and mixed-width scripts can make columns appear irregular even though their underlying order is correct. Always preview the result in the final destination font before publishing it.
The practical choice is direct: use the online Vertical Text Generator for a quick interactive result, especially when you need to inspect, copy, or download one arrangement. Build a command-line version only when repeated automation justifies maintaining and testing your own Unicode-aware implementation; there is no documented Lizely CLI to invoke. For accessible websites or controlled print output, choose CSS or a design application instead of treating plain-text columns as full typography.
If you're weighing options, Add Line Numbers to Text on iPhone: Plain-Text Workflow covers this in detail.
If you're weighing options, How to Add Suffix to Lines While Preserving Their Text covers this in detail.