Make the plot correctly by entering one strict numeric x,y pair per non-empty line, then verifying the valid, invalid, and over-limit counts, both linear axis ranges, and several representative points before downloading.
A generated chart can look plausible even when some rows were skipped or its scale does not support the interpretation you intended. The Scatter Plot Maker converts supplied pairs into a two-axis visualization in your browser. The reliable approach is to check the source format, reconcile the row counts, read the axes, and inspect the exported result separately.

Set the expected meaning of every point
Each accepted row represents one observation. The first number is x, which determines the horizontal position, and the second is y, which determines the vertical position. Every valid pair becomes one blue circle.
Both axes use independent linear numeric scales. A larger numerical gap occupies more space than a smaller gap, so x positions are not automatically evenly spaced. Correctness means that every intended point was included, each marker sits where its values place it, and any skipped input is disclosed. It does not mean the chart has established a statistical relationship.
Prepare rows that the strict parser can read
Paste only numeric pairs, with exactly one comma between the x and y values. Signed numbers, decimals, zero, and scientific notation are accepted. Do not add a column heading because it is not a numeric pair and will be counted as invalid. Blank lines are ignored, and negative zero is normalized to zero.
| Example row | Result | Reason |
|---|---|---|
| 12,7 | Valid | Two finite numeric values |
| -3.5,0.25 | Valid | Signed values and decimals are supported |
| 1e3,-2e-2 | Valid | Scientific notation is supported |
| 1,,2 | Invalid | One component is empty |
| 1,2,3 | Invalid | The row contains extra comma-separated components |
| 12kg,2 | Invalid | Unit text is not accepted |
| 0x10,2 | Invalid | Hexadecimal notation is not accepted |
| Infinity,2 | Invalid | Only finite numbers are accepted |
| NaN,2 | Invalid | NaN is not a finite numeric value |
| 10000000000000,2 | Invalid | The magnitude is above 1e12 |
The complete input may contain no more than 50,000 UTF-16 code units; a larger input is rejected rather than partially processed. The point limit works separately: only the first 200 non-empty rows are parsed and checked. Every additional non-empty row is counted as an over-limit skip rather than as an invalid row. Those later rows are not plotted or checked for formatting. Keep the original dataset so you can confirm that the chart represents the rows you intended.
Build and verify the plot
- Save the source and add a title. Keep a separate copy of the original rows before pasting them. Enter an optional descriptive title in the title field. The title is escaped before it enters the SVG, so markup-like text remains visible text rather than creating chart elements.
- Paste one pair per line. Use the form x,y for every non-empty line. Remove headers, units, extra commas, and non-numeric text before generating the plot. Do not assume that a line was accepted merely because it appears in the input area.
- Generate the chart. After the data and title are set, generate the plot. The result summary reports valid points, invalid rows, and over-limit rows as three separate numbers, including zero for any category that has no rows.
- Reconcile the counts. Confirm that the valid and invalid counts together account for the non-empty rows among the first 200 checked. Treat the over-limit count as a separate group of additional rows that were not parsed. If no valid point remains, the tool reports an error and clears any older chart rather than presenting an empty or misleading result.
- Read both axis ranges. Check the smallest and largest displayed values on the horizontal and vertical axes. Five labeled reference lines expose each range. The smallest x value maps to the left boundary and the largest to the right; the smallest y value maps to the bottom and the largest to the top.
- Inspect representative points. Compare several source rows with their plotted positions and marker titles, including points near the range boundaries. Each circle contains a text title with its exact formatted x and y values for SVG-aware viewers. Overlapping markers can conceal one another, especially when identical pairs repeat, so one visible circle does not necessarily mean only one observation was parsed.
- Download after the checks pass. The standalone SVG represents the same generated string used for the preview; it is not reconstructed separately. If you edit the title or data afterward, the old generated string is cleared and its download is disabled. Regenerate and repeat the relevant checks before exporting again.
Read linear and constant axes correctly
Because the axes do not automatically include zero, the apparent height or spread of a cluster can be misleading until you inspect the labels. Values are positioned in direct proportion to their numerical distance within each displayed range. If you expect category-like spacing, review the difference between numerical and categorical positioning in Are X Positions Equally Spaced in a Scatter Plot Maker?
A constant axis receives special handling so that equal minimum and maximum values do not cause invalid coordinates. When all x values are identical, the x domain expands symmetrically around that value and centers the points horizontally. The same rule applies independently to a constant y value. The expansion is ten percent of the absolute constant or one unit, whichever is larger. As a result, a single valid point appears at the center of both axes instead of failing.
Use validation counts to diagnose the result
Use the separate counts and chart behavior to determine what needs correction rather than guessing from the marker pattern alone.
| Observation | What it means | Correct response |
|---|---|---|
| Invalid count is above zero | One or more of the first 200 non-empty rows failed the strict numeric rules. | Repair the affected source rows and regenerate. |
| Over-limit count is above zero | Additional non-empty rows occurred after the first 200 and were not parsed. | Use a dedicated plotting package if every row must appear in one chart. |
| Valid count is zero | No checked row produced a usable numeric pair. | Fix the source format; the older chart has been cleared. |
| All x or all y values are identical | The affected axis required a symmetric expanded domain. | Confirm the displayed range and do not infer variation from the centered placement. |
| Visible markers seem fewer than valid points | Close or identical points may be overlapping. | Inspect point titles and compare against the source rows. |
Do not combine the invalid and over-limit figures to claim that every pasted row was processed. Invalid rows were examined and failed parsing, while rows beyond the 200-row checking boundary were deliberately left unparsed. Both groups are omitted from the chart, but their different meanings should remain clear in your notes.
Verify the downloaded SVG
The output is a standalone 800 by 500 SVG with a white background, title, grid, numeric axis labels, and point markers. SVG is a vector format, so lines, text, and circles remain sharp when resized; MDN's SVG tutorial provides a useful reference for the format. The preview and download use the same percent-encoded SVG data URI, which helps ensure that the file matches the chart you inspected.
Coordinates in the SVG are rounded to three decimal places, and axis labels use practical significant digits or scientific notation for very large and small values. Calculations use JavaScript double-precision floating point. The chart is therefore a visualization, not a precision-preserving data format, so retain the original rows for exact values, reproducibility, and later analysis.
Parsing, coordinate calculation, SVG creation, preview, and download preparation all happen locally in the current browser tab. No points or title are uploaded to Lizely.
Know when the visualization is not enough
This maker plots supplied pairs on linear axes; it does not calculate correlation, regression, a trend line, confidence intervals, error bars, density, clusters, or statistical significance. It can support a rough visual inspection of small experiments, paired observations, calibration samples, classroom examples, and similar datasets. For dense data, categorical color, accessible labeling, logarithmic scales, publication styling, or formal statistical analysis, use a dedicated plotting package and retain the source dataset.
For a deeper look, see Bar Chart Maker Tips and Common Mistakes to Avoid.